uptime for the system. The below table has precalculated the most common requirements:
Hours Uptime
12 Hr
24 Hr
Referencing the above table, a site needing 12 hours of uptime for three TD100 units would
purchase two 12 VDC 24 amp-hour (AH) batteries. Uptime extending past the above table
should consider alternatives to batteries such as backup generators.
WARNING: Do not touch exposed metal parts with battery leads. Turn off (Shut) branch
circuit power before installing or servicing equipment. Be aware that while making the
battery connections to the LPS5, sparking may occur.
To connect batteries in series one "Negative," typically black, (-) terminal from one battery
would connect to the "Positive," typically red, (+) terminal of the second battery.
The remaining negative and positive terminals would connect to the "BAT" screw terminals
located next to the "AC" LED on the LPS5. The positive terminal is on the left and negative
on the right regarding the PCB "BAT" label.
Page 57
TD100 Units
1
4 Hr
3 AH
8 AH
16 AH
Figure 70. Battery connection to the LPS5
2
3
5.5 AH
8 AH
16 AH
24 AH
32 AH
48 AH