Product Specifications; Td100™ Processor; Tdr8™ Relay Module - Optex Fiber SenSys Terrain Defender TD 100 Installation Manual

Table of Contents

Advertisement

11. Product Specifications

TD100™ Processor
System Type
Sensing TX/RX
Power Specifications
Communications
Front-Panel Display
Environmental
Dimensions
Point Resolution
Detection Field
Sensing Cable
Insensitive Lead-in
Standards and
Certifications
TDR8™ Relay Module
System Type
Power Specifications
Communications
Relay Outputs
Relay Inputs
Page 80
Buried line, point locating, sensor for perimeter security
Two fully independent TX/RX pairs
15 m (49 ft) virtual zone minimum
Input: 24 – 48 VDC, 12 Watts
TCP/IP port for remote configuration and alarm output
(future)
RJ-45 port for TDR8
LED indicators for initialization, armed, warning, and tamper
Temperature: -40˚ C to 70˚ C (-40˚ F to 158˚ F)
Humidity: 0 to 95% non-condensing
Height: 14.78 cm (5.82 in)
Width: 25.43 cm (10.01 in)
Depth: 8.20 cm (3.23 in)
Within 1 m (3.3 ft) location accuracy
Height: 1 m (3.3 ft)
Width: 2 – 3 m (6.6 – 10 ft)
Length: Up to 400 m (1312 ft) per RX/TX pair
*See TDSC and Lead-in Cables specification section
Length: 10 m (30 ft) standard
o Contact Fiber SenSys for custom lengths
*See TDSC and Lead-in Cables specification section
FCC Part 15 Class B, ISED, IEC 62368-1:2018
Relay I/O, TD100 optional accessory
Powered via TD100 connection
RJ-45 Port for connection to TD100 processor, 30 ft cable
length maximum
8 Individual, configurable (Alarm, Tamper, Fault) dry
contact relays
Normally Open (NO) and Normally Closed (NC), Form C
24 to 12 AWG
1 A, 30 VDC non-inductive
Dry Contact Resistance .100 Ω max
4 Individual dry contact relays