Td24Psu - Optex Fiber SenSys Terrain Defender TD 100 Installation Manual

Table of Contents

Advertisement

Environmental
Dimensions
Standards and
Certifications

TD24PSU

System Type
Power Input
Power Output
Battery
Relay Outputs
Front-Panel Display
Environmental
Dimensions
Page 81
Normally Open (NO) and Normally Closed (NC)
configurable via WUI
24 to 12 AWG
Temperature: -40˚ C to 70˚ C (-40˚ F to 158˚ F)
Humidity: 0 to 95% non-condensing
Height = 10.9 cm (4.3 in)
Width = 19.60 cm (7.72 in)
Depth = 4.24 cm (1.67 in)
FCC Part 15 Class B, IEC 62368-1:2018
TD100 Power Supply Unit
3 Units upported (Max)
115 – 240 VAC
Input Frequency: 50/60 Hz
Short circuit and thermal overload protection
Filtered and regulated
Output: 24 VDC, 3.5 A
Output Fuse Rating: 400 VDC – 2.0 A, Time Delay / Slow
Blow
Fuse Size / Case: 6.3 mm x 32 mm (25 in x 1.25 in) –
3AG / Cartridge Fuse
• Built-in charger for sealed lead acid or gel type batteries
• Automatic switch over to stand-by battery when AC fails
(zero voltage drop)
• PTC battery protection
• Maximum charge current 0.3 A
Dry Relay Outputs 1A @ 28 VDC
Form "C" contacts (NC, NO, C)
• AC Fail Supervision
• Low Battery
LED indicators for AC power and DC power
Temperature:
0° C to 49° C (32° F to 120° F)
Humidity: 85% +/- 5% non-condensing
AC Transformer:
Width = 14 cm (5.5 in)
Length = 7.4 cm (2.9 in)
Depth = 7.3 cm (2.9 in)
LPS5:
Width = 17.8 cm (7 in)
Confidential – Limited Distribution