TD48PSU

System Type
Power Input
Power Output
Front-Panel Display
Environmental
Dimensions
Page 82
Length = 10.2 cm (4 in)
Depth = 6.27 cm (2.47 in)
DP4:
Width = 8.3 cm (3.25 in)
Length = 7.6 cm (3 in)
Depth = 1.9 cm (0.75 in)
TD100 Power Supply Unit
6 Units supported (Max)
120 – 240 VAC
Input Fuse Rating: 250 VAC – 1.5 A, Time Delay / Slow
Blow
Input Frequency: 47 Hz to 63 Hz
Output: 48 VDC, 3 A
Output Fuse Rating: 300 VDC – 2.0 A, Time Delay / Slow
Blow
Fuse Size / Case: 5 mm x 20 mm / Cartridge Fuse
LED indicators for AC power, DC power, and fuse blow (3)
Temperature:
0˚ C to 55˚ C ( 2˚ F to 1 1˚ F)
Up to 6 total TD100 (Max)
0˚ C to 70˚ C ( 2˚ F to 158˚ F)
Up to 3 total TD100
Humidity: 5 to 95% non-condensing
Height = 28 cm (11 in)
Width = 28 cm (11 in)
Depth = 4.24 cm (5.07 in)
Confidential – Limited Distribution