System Planning - Optex Fiber SenSys Terrain Defender TD 100 Installation Manual

Table of Contents

Advertisement

3. System Planning

Survey the Site
Every site is unique, and each with its challenges. To ensure the best performance of the
TD100 system, this section will help guide you through the process and provide you the tools
needed for the best design and solution.
Note: Please contact Fiber SenSys to help you with your TD100 site design
As comprehensive as these manuals are, the TD100 is intended to be installed by
trained professionals. This is essential to optimize the performance of the system at any site.
Check List
CAD/PDF Drawings pertaining to Perimeter Intrusion Detection System
o Show location of:
o Fences (Type, Height, Condition, Distance from sensor cable)
o Proposed cable path on drawing
o Gates (Single, Dual)
o Driveways, Walkways
o Soil Type
o Describe soil type. Example: sandy, dry granular, loam, clay, heavy clay, etc.
o Concrete
o Thickness
o Reinforced Yes/No
o Asphalt
o Thickness
o Reinforced Yes/No, Fiber/Metal
o Stone/Crush Rock
o Thickness
o Water
o Irrigation Pipes (Metal/Plastic)
o Drainage Pipes (Metal/Plastic)
o Shoreline (Lake, River, Stream)
o Run-Off Ditches
o Sewer Pipes (Metal/Plastic)
o Electrical
o Conduit Raceways (Metal/Plastic)
Photographs/Video
o If an existing site, provide pictures and/or video clips of the detection areas
o Description of local weather conditions
o Provide address and/or GPS coordinates
Page 22
If more than one soil type, show change
Confidential – Limited Distribution