No.59-2643-0 171013 Installation Instructions Vehicle Detection Sensor for Gate OVS-01GT Table of Contents Safety Precautions Component Name Features Before Using the Product Detection Principle and Basic Operation of the Sensor Vehicle detection is ensured by a combination of ● Sensor Installation Recommendations microwave and ultrasonic wave.
Safety Precautions This product is a vehicle detection sensor designed for activation and presence of a vehicle, installed close to the gate operator. Do not use the product for other purposes. For Safe Use About the Marks The description given here is for correct usage of the product without causing damage to you, other personnel as well as damage to properties.The marks and their meanings are as follows: Please read the text after understanding the contents well.
Component Name Sensor Unit Operation Unit Front Cover Sensor Unit Base ■ Operation Unit Sensitivity Human Cancel Adjust Mode Indicator Presence Detection Timer (min) Infinity Sensitivity Boost Timer (sec) Ultrasonic Maximum Range (m) Input Wake L Wake H Inhibit L Inhibit H Value button Mode Selection button...
Before Using the Product Detection Principle and Basic Operation of the Sensor ● Detection Principle This sensor uses reflection of a microwave and ultrasonic to detect a vehicle. ● (The higher the reflection, the easier the detection becomes.) The microwave sensor uses FMCW technology, it can detect the presence of a vehicle. ●...
Sensor Installation Recommendations There are two (2) types of sensor installations. Choose one depending on the site conditions from the following. The sensor will not work correctly unless the installation directions, height, and operation type are correct. ● Barrier Gate Gate Bar Vehicle Path 700mm(27.56in.)
Do not install any moving object such as flags or banners in the sensor's detection NOTE ● area. Remove any vegetation from the detection area, or reconfigure the detection area to be smaller. Not following these steps may stop the sensor reverting back to non-detection status or delay the change of status.
Installation Workflow Shown below is the sensor installation workflow. Please read carefully before installation. [1] Checking Installation Location: Go to P.5 Verify that the installation location meets the installation conditions. [2] Unit Installation: Go to P.9 Remove the front cover and sensor unit, and attach the sensor and connect the wire.
Page 8
[5] Detection Area Check: Go to P.14 Verify the detection area.If needed, change the installation angle of the unit and/or sensing distance setting. * Once the installation condition such as the angle is modified, perform the calibration again. Sensitivity Human Cancel Adjust Presence Detection Timer (min) Infinity Sensitivity Boost Timer (sec)
Installation Steps (Basic) Installation of the Unit ■ Required Tools ■ ●Precision screwdriver, Phillips #1 ●Screwdriver, Phillips #2 [1] Drill pilot holes into the poles and attach the sensor. Mounting Pitch 32±1 (1.26±0.04) [Unit : mm(inch)] [2] Run the wire through the poles. [3] Fix the poles so that the each sensor faces the angle shown below.
Page 10
[4] Loosen the retaining screws on the bottom of the front cover and remove the front cover. * Do not loosen the screw completely. The screw may fall out. If losing the screw, use a M3 x 10 philips screw. [5] Detach the sensor unit.
Page 11
[8] Attach the sensor unit to the base. Press the excess wire back into to the pole while attaching the unit. [9] Perform the steps in P.12 through 15 "4-2 Setting Verification and Adjustment", "4-3 Calibration", and "4-4 Detection Area Check". [10] Put the front cover on the top of the base first, and attach it while spreading it open and pushing down the front cover.
Setting Verification and Adjustment Sensitivity This section describes how to verify the basic settings. Use the Human Cancel Adjust buttons to change the settings if needed. Presence Detection Timer (min) Infinity Sensitivity Boost Timer (sec) Ultrasonic Maximum Range (m) Input Wake L Wake H Inhibit L...
Calibration ●Calibration function This function records (memorizes) the background of the detection area without any pedestrians or vehicle present. This process makes the sensor detection capability higher and provides stable detection. If any noticeable changes occur around the detection area (such as construction of a wall or fence), you must perform the calibration again.
Detection Area Check ● Detection Area Check Function This function allows you to visually check the detection area of the microwave and ultrasonic signal using the operation indicator. It is possible to verify the correct angle and size of the detection area. *This detection area check must be performed after calibration.
Page 15
[3] Stand at the edge of the vehicle lane (see Figure [B]), walk along the border and verify that the operation indicator keeps blinking green (not detecting). If the operation indicator changes to yellow or red, adjust the sensor angle and/or range setting again. After the adjustment, perform calibration again and start from [2].
Other Functions ● Automatic Indicator OFF If a button is not pressed for 30 minutes, the operation indicator dims and other indicators turn off. Pressing any button turns the indicators back on. Standby Area Check Operation Indicator Detection Calibration Calibration Error Calibration Area Check ●...
Advanced Installation The following setting parameters are to be configured if the sensor does not operate as expected in the system operation check or some error occurred. They are not necessary for a normal installation. Sensitivity Sensitivity setting and vehicle detection capability have the following relationship. Factory default setting: In normal cases, use with the sensitivity level of 3.
Human Cancel Adjustment The human cancellation setting and human cancellation capability have the Factory default setting: following relationship.In normal cases, use with the level of 3. Sensitivity Setting Human Cancel Adjust Presence Detection Timer (min) Infinity Sensitivity Boost Timer (sec) Human cancellation Ultrasonic Maximum Range (m) High...
Presence Detection Timer The presence detection timer periodically performs automatic calibration. It can Factory default setting: prevent the sensor from detecting an object for a long period of time. 5min If there is any of the following problems, configure the presence detection timer. The sensor keeps detecting due to an object in the detection area.
Page 20
● How to Change the Presence Detection Timer [1] Press the Mode Select button and select [Presence Detection Timer] the mode indicator (red).Every time pressing the button, the mode indicator moves down by one. [2] Press the Value button and select the desired time period of the setting indicator (green). Keep pressing the button until the desired setting is reached.
Sensitivity Boost Timer * Use only if the Sensor Mode is configured as [Vehicle Protection] The Sensitivity Boost Timer enhances the sensitivity for a certain period of time Factory default setting: after a vehicle has passed through the detection area. Enable this function if a vehicle may back up unintentionally due to an slope in the exit area.
Ultrasonic Maximum Range If an error occurs due to an object that cannot be relocated such as the gate, avoid Factory default setting: the error by reducing the range of the ultrasonic sensor. 1m(3.28ft.) ● How to adjust the Ultrasonic Sensor range. [1] Press the Mode Select button and select [Ultrasonic Maximum Range] the mode indicator (red).
Input Wake up ● When using the input for vehicle protection, it is possible to use an external input Factory default setting: to trigger a sensitivity enhancement. Wake L [1] Connect the signal wire from an activation sensor or keypad to the input terminal. [2] To connect to a N.C.
Troubleshooting Symptom Cause Action Operation indicator does not turn ON. Power may not be supplied. Connect power supply of 12-24VDC. The supply voltage may not be correct. Check Power supply voltage 12-24VDC. The power supply polarity is wrong Check power supply polarity. (wrong polarity does not cause a failure but the product does not work).
Page 25
Symptom Cause Action The sensor detects a vehicle outside of Sensitivity may be too high. Reduce sensitivity. the detection area. The sensing distance of the microwave Reduce the sensing distance of the may be too long. microwave. The direction of the sensor (detection Adjust the sensor (detection area) area) is not correct.
Detection Area Diagram Microwave Top View Side View Ultrasonic 5.5m setting 5.5m setting [Unit : m] Installation height 0.5m(1.64ft.), Operation type: Device activation, Sensitivity: 3, 1m=3.28ft. Ultrasonic sensor sensing distance: 1m(3.28ft.), Detection area check mode * Under normal operation, the detection area by an actual vehicle may be smaller. Dimensions [Unit : mm(inch)] Cable Hole 14(0.55)
Page 28
Hereby, OPTEX declares that the radio equipment type OVS-01GT isin compliance with RED 2014/53/EU. The full text of the EU DoC is available at the following internet address: www.optex.net EU contact information Manufacturer: OPTEX CO., LTD. 5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN Authorised representative in Europe: OPTEX (EUROPE) LTD.
Need help?
Do you have a question about the OVS-01GT and is the answer not in the manual?
Questions and answers