Step 6 - Optex Fiber SenSys Terrain Defender TD 100 Installation Manual

Table of Contents

Advertisement

Step 6

Using the TD100 Coax Cable Strip Template seen in,
jacket from the end of the cable 75 mm (3 in) using the adjustable blade ringer,
Figure 39. Stripping the sensor cable using the DW-ENG-51 template
It is preferable to score the second polyethylene (PE) jacket but DO NOT cut through the
second jacket. Without caution, this procedure may sever the shield layer and/or drain wire;
if either is cut, the process must be redone. Because of this, it is best to set the blade depth
of the ringer using scrap sensor cable or the end ~10mm (.4 in) of the sensor cable before
making the 75 mm (2.95 in) ring cut.
CAUTION: If the shield or drain wire is nicked or cut within the stripped cable end, the
procedure must be restarted. There should be enough spare cable to attempt this
process three times.
Page 40
Figure 40. Sensor Cable Strip Template (not to scale)
Figure
40, cut through the outer PVC
Confidential – Limited Distribution
Figure 41.