13

Maintenance

・ To clean the sensor, lightly wipe with a clean, soft cloth and
water diluted with a mild detergent, and then wipe with a dry,
Caution
soft cloth.
・ Do not wipe the sensor with organic solvent such as benzine.
・ Do not put oil such as grease on a wiper blade.

Maintenance (monthly)

Perform the following operations every month.
・ Clean the detection window and wiper blade using tap water.
・ Inspect the detection window for damage and/or degeneration.
・ Inspect the wiper blade for wear and/or deformation.
・ Inspect the wiper blade that it is tightly fixed.
・ Inspect the sensor cable for damage and/or degeneration.
・ Inspect the hanging bracket for corrosion.
・ Immerse the sensor in measurement water of the known concentration
and check that the correct value is displayed on the transmitter.

Periodic inspection (every 3 months)

Perform the following inspections every 3 months.
・ Terminal block screws of the transmitter are not rusted.

Replacement of consumables

・ Replace the wiper blade once a year as rough standard. In addition,
replace it when adequate wiping effect cannot be produced. When
replacing the wiper blade, replace the blade stays and mounting screws at
the same time.
・ Replace the lifting lug once a year as rough standard. In addition, replace
it when it is corroded significantly.
・ Replacement wiper blade and hanging bracket are included in the optional
maintenance kit (TC-MK). For replacement, purchase TC-MK.