Chapter 6 Operations and Measurements
threshold of Source A (or Source B) in logic operation. For setting methods,
refer to descriptions in "Parameter Setting Method".
Click Offset to adjust the vertical offset of the operation results.
⚫
Click Size to select the waveform size. The available sizes include "Small",
⚫
"Medium", and "Large".
The AutoSetting menu is grayed out and disabled.
⚫
Click More → Sensitivity to set the sensitivity of the digital signal converted
⚫
from the analog signal on the source. For setting methods, refer to descriptions
in "Parameter Setting Method".
Click More → Label to set the label for math operation results. For details, refer
⚫
to descriptions in "Math Operation Label".
Intg
Calculates the integral of the selected source. For example, you can use integral to
measure the area under a waveform or the pulse energy.
Click Math → Math1 → Operator to select "Intg":
Click Operation continuously to enable or disable the "Intg" operation function.
⚫
Click SourceA to select the channel for Source A. The available channels for
⚫
Source A are CH1-CH4 and Ref1-Ref10.
Note:
The source of Math2 can be CH1-CH4, Ref1-Ref10, or Math1; the source
of Math3 can be CH1-CH4, Ref1-Ref10, Math1, or Math2; the source of Math4
can be CH1-CH4, Ref1-Ref10, Math1, Math2, or Math3; only the channels that
have been enabled currently can be selected.
Click Offset to set the vertical offset of the operation results. For setting
⚫
methods, refer to the descriptions in "Parameter Setting Method".
Click Scale to set the vertical scale of the operation results. For setting methods,
⚫
refer to the descriptions in "Parameter Setting Method".
Click AutoSetting to adjust the vertical scale and offset of the operation results
⚫
to an optimal value based on the current configuration, so as to better observe.
Click More → Bias to set the DC offset correction factor for the input signal.
⚫
Note that this parameter can only be set by using the numeric keypad.
Click More → Invert to enable or disable the inverted display function of the
⚫
waveform.
Click More → Label to set the label for math operation results. For details, refer
⚫
to descriptions in "Math Operation Label".
Click More → Color Grade to enable or disable the color grade display of the
⚫
operation results. When enabled, different colors are displayed on the screen to
indicate the times of data acquisition or acquisition probability.
Click More → Reset ColorGrade to clear the color grade display and display
⚫
the color grade again.
DS8000-R User Guide
RIGOL
6-13