RIGOL
Main
Time
Base
Time
Base of
the
Delayed
Sweep
Waveform before enlargement:
The waveform in the area that is not covered by subtransparent blue in the upper
part of the screen is the waveform before enlargement. Its horizontal time base (also
called main time base) is displayed at the upper-left corner of the screen.
Waveform after enlargement:
The waveform in the lower part of the screen is the horizontally expanded delayed
sweep waveform. Its horizontal time base (also called the time base of the delayed
sweep) is displayed on the screen. Compared with the main time base, the time
based of the delayed sweep has increased the waveform resolution.
Note:
The time base of the delayed sweep should be smaller than or equal to the
main time base.
3-4
Waveform Before Enlargement
Waveform After Enlargement
Figure 3-1 Delayed Sweep Mode
Chapter 3 To Set the Horizontal System