RIGOL
Horizontal Direction. Therefore, the maximum number of frames of waveform
recording is also related to the "Sample Rate" and "Horizontal Time Base". This
oscilloscope provides ceaseless recording for a maximum of 450,000 frames of
real-time waveforms.
4. Beeper
Click Beeper continuously to set whether the beeper sounds when the
recording is completed.
: the beeper sounds at the end of recording.
⚫
: the beeper does not sound at the end of recording.
⚫
Play Options
Waveform playing function can play back the waveforms currently recorded. Before
playing back the waveforms, you can click More → Setting to select "Play" to set
the following parameters.
1. Play Mode
Click Mode continuously to set the playback mode to
(single).
: plays back repeatedly until you stop it manually.
⚫
: plays for a single time, and then stops automatically.
⚫
2. Playback Sequence
Click Sequence continuously to select the playback sequence to
clockwise) or
: plays from the start frame to the end frame.
⚫
: plays from the end frame to the start frame.
⚫
3. Playback Interval
The playback interval indicates the time interval between the frames during the
playing process.
Click Interval, then use pop-up numeric keypad or scroll with the mouse to set
the time interval between frames. The available range is from 5 ms to 10 s.
4. Start Frame
Click Start Frame, then use pop-up numeric keypad or scroll with the mouse to
set the start frame for playing back the waveforms.
5. End Frame
Click End Frame, then use pop-up numeric keypad or scroll with the mouse to
set the end frame for playing back the waveforms.
14-4
(playback counterclockwise).
Chapter 14 Waveform Recording & Playing
DS8000-R User Guide
(cycle) or
(playback