Slide-Out Manual Override Procedure - PREVOST H3-45 VIP Owner's Manual

Hide thumbs Also See for H3-45 VIP:
Table of Contents

Advertisement

FIGURE 3: FAST IDLE BUTTON
Slide-out Extending Operation
With the ignition switch to the "ON" position and
the engine running, press and hold down the rocker
switch on the control pad to the "OUT" position.
The
green
indicator
OPERATION" will come on to indicate that the
slide- out operation cycle is activated. The
following actions will be done in sequence:
Deflation of the inflatable seal
l
Movement of the slide-out to its full "OUT"
l
position
Optional flush floor rises, slight retract of the
l
room to secure and reduce gaps in flooring.
Then releasing the rocker switch will permit the
following actions:
Re-inflation of the seal
l
When the rocker switch is released, the green
indicator light goes out. Note that for safety
reasons, releasing the rocker switch will stop the
slide- out movement instantly. At any time,
releasing the rocker switch from the "OUT"
position and pressing it to the "IN" position will
reverse the operation.
CAUTION
The inflatable seals can be re-inflated only when
the slide-out is in its full "OUT" or full "IN" position.
Do not leave the slide-out in any position other than
the full extended or closed position as water
infiltration may occur. The indicator light on the
control pad must be OFF.
NOTE
A green blinking light on the control pad indicates
an error condition or missing operation condition on
the corresponding slide-out. Refer
TROUBLESHOOTING"
situation occurs.
light
"ROOM
IN
to"SLIDE-OUT
on
page 37
if
that
PA-1619 Owner's Manual H3-45 VIP
FIGURE 4: SLIDE-OUT CONTROL PAD
Slide-out Retracting Operation
With the ignition switch to the "ON" position and
the engine running, press and hold down the rocker
switch to the "IN" position to retract the slide-out.
Note that the green indicator light "ROOM IN
OPERATION" will come on. When the movement
of the slide- out to its full "IN" position is
completed, the rocker switch can be released to
allow the re- inflation of the seal. The green
indicator light goes out as the rocker switch is
released. At any time during the slide- out
movement, releasing the rocker switch will stop
the operation instantly.
CAUTION
The inflatable seals can be re-inflated only when
the slide-out is in its full "OUT" or full "IN" position.
Do not leave the slide-out in any position other than
the full extended or closed position as water
infiltration may occur.

SLIDE-OUT MANUAL OVERRIDE PROCEDURE

CAUTION
Never use an impact power tool to manually
operate the slide-out. Doing so would damage
the various mechanical components of the slide-
out.
Do not over extend or over retract the slide-outs.
Always refer to the slide-out decal for correct
direction of rotation (clockwise or counter
clockwise).
In case of power retracting system failure, it is
possible to use the manual override procedure to
retract or extend the slide-out.
Other Features 5-33