B-8 Multiplex Troubleshooting
Problem / Symptom
The vehicle is parked and
the
electrical
horn
activated to indicate a fire
in
the
engine
compartment but there is
no fire
A single light, a group of
LED lights or another
function of the vehicle is
not functioning
No backlighting in the
instrument cluster
The radiator/CAC electric
fans do not function and
the engine is overheating
Probable Causes
Short-circuited fire sensor or
is
defective sensor
The multiplex outputs are
protected in current by an
internal "soft fuse". When an
output is shorted, it turns
OFF and stays OFF until the
"soft fuse" is reset
Circuit
breaker
tripped
or
fuse
blown
PA-1619 Owner's Manual H3-45 VIP
Cycle the ignition key between the ON and
OFF position twice within 3 seconds. This
will deactivate the fire alarm function. This
has to be repeated each time the vehicle is
parked
turn the ignition key to the OFF position and
turn to the ON position again. This resets all
"soft fuses"
CB10
is
Check circuit breaker CB2, CB10
F10/F29
Check / replace fuse F10, F29
Check / replace relay R22, R23
You can manually engage the radiator/CAC
fans half-speed (50%) or full speed (100%).
1. On the Driver Information Display,
select DIAGNOSTICS menu. Select
VEHICLE TESTS submenu and then
FORCE RADIATOR FAN SPEED
50% or FORCE RADIATOR FAN
SPEED 100%.
2. The DID status line will show TEST to
confirm the forced activation of the
radiator fans. To cancel, turn the
ignition switch to the OFF position or
press
TERMINATE TESTS & FORCED
STATES submenu and then press
ENTER
disappear from the DID status line.
Actions
ESCAPE
button,
button twice.
TEST
select
will