5-36 Other Features
Manual Extending Procedure – Front And Rear
Slide-out
1. Apply barking brake to disengage the security
pin from the receptacle.
2. Turn the ignition switch to the "OFF" position,
and remove the ignition key for more safety.
3. Deflate the inflatable seal by using the
relieving shut-off valve located in the slide-out
control panel. Turn the handle clockwise to
deflate the seal. Make sure the pressure
indicator reading is "0 psi".
CAUTION
The pressure in the inflatable seal must be
completely relieved to prevent any damage to the
seal.
NOTE
When air pressure is relieved using the shut-off
valve, the normal extending and retracting
operation cycle is disabled, for that reason the
slide-out cannot be moved with the control pad.
FIGURE 9: PNEUMATIC CONTROL PANEL
NOTE
Refer to the slide-out decal for correct direction of
rotation (clockwise or counter clockwise).
4. To move the slide-out, use a cordless power
drill with a 3/8" hexagonal bit on the shaft
extension of the slide-out motor.
5. Rotate the slide- out motor shaft extension
6. Once the slide-out is lined up to its opened
FIGURE 10: SLIDE-OUT MOTOR MANUAL ACTIVATION
NOTE
The front slide-out motor is located inside the 2nd
baggage compartment while the rear slide- out
motor is accessible from inside the vehicle, under
the bed structure..
Slow down on the closing speed as the slide-out
approaches its extended position. As soon as the
"out limit" stoppers come in contact with their
bearing surface, stop immediately the power drill
rotating movement. Not doing so could overload
the drive mechanism and cause damage to the
reduction gearbox.
7. Finally, the inflatable seal can be re-inflated
PA-1619 Owner's Manual H3-45 VIP
with the power drill until the slide-out comes
to its opened position.
position, remove the tool from the motor.
CAUTION
by
turning the shut- off
counterclockwise. Check the pressure gage
on the inflatable seal regulator to see if the
pressure is increasing to around 15 psi.
Needle should point between the green
indicator pegs.
valve handle