5-34 Other Features
The manual override procedure consist in rotating
the slide- out motor shaft extension using a
cordless power drill with a 3/8" hexagonal bit.
However, it is very important to follow all the
instructions very carefully to assure that the
inflatable seal or the retraction mechanisms are
not damaged.
CAUTION
Manually extending the optional front right
Prevost slide- out with flush floor should be
attempted with extra care as a last resort.
Serious damage to the mechanical components
may result.
This particular slide-out configuration uses two
electronically synchronized motors for room
extension. As a result, manually extending the
room is not recommended.
Refer to the procedures and guidelines in the
maintenance manual.
However the floor lifting portion of the
mechanism can be hand operated. Refer to
particular instructions below.
Preliminary Conditions For Manual Override
Procedure
Before using the slide- out manual override
procedure, make sure that the problem cannot be
solved by one of the following simple checks:
Make sure that none of the breakers are
l
tripped (the breakers are located inside the
VEC on the slide-out control panel and the
main slide-out breaker is located in the engine
R.H. side access compartment).
Make sure the parking brake is applied and
l
that transmission is in the "NEUTRAL"
position.
Make sure the voltage is high enough by
l
running the engine at fast idle or having the
battery charger connected.
CAUTION
Before extending or retracting the slide-out, always
open a window to avoid movement restriction and
to prevent the motor from stopping in over current
because of a vacuum or pressure build up inside
the vehicle.
FIGURE 5: SLIDE-OUT CONTROL PANEL
Manual Retracting Procedure – Front And Rear
Slide-out
1. Turn the ignition switch to the "OFF" position,
2. Deflate the inflatable seal by using the
The pressure in the inflatable seal must be
completely relieved to prevent any damage to the
seal.
NOTE
When air pressure is relieved using the shut-off
valve, the normal extending and retracting
operation cycle is disabled, for that reason the
slide-out cannot be moved using the control pad.
PA-1619 Owner's Manual H3-45 VIP
and remove the ignition key for more safety.
relieving shut-off valve located on the slide-
out control panel. Turn the handle clockwise
to deflate the seal. Make sure the pressure
indicator reading is "0 psi".
CAUTION