Mobile Floor Hand Crank Procedure; Slide-Out Troubleshooting - PREVOST H3-45 VIP Owner's Manual

Hide thumbs Also See for H3-45 VIP:
Table of Contents

Advertisement

FIGURE 11: INFLATABLE SEAL PRESSURE GAGE
NOTE
The slide-out control system inhibits transmission
range selection to prevent the vehicle from moving
if the slide-out is not in its full "IN" position.

MOBILE FLOOR HAND CRANK PROCEDURE

The floor lifting mechanism of the front right (curb
side) slide-out room can be manually operated in
the event of a power failure. You will need a 6mm
(1/4") Allen key to operate the actuator.
CAUTION
Do not use an electric drill or other similar tool to
operate the linear actuator. Permanent damage to
the unit may result.
As a safety measure, unplug the unit before
attempting to hand crank the unit.
NOTE
If the actuator is operated as a hand crank, it
must only be operated by hand, otherwise there
is a potential risk of overloading and hereby
damaging the actuator.
Hand Crank Torque: 6-8 Nm.
Hand Crank Max Speed:. 65 rpm
The actuator is located under the floor in the
second right luggage compartment.
After removing the cover (4 screws), locate the
hand crank hex socket on the actuator (arrow
below).
FIGURE 12: MOBILE FLOOR HAND CRANK HEX
SOCKET LOCATION
The cover over the Allen Key socket must be
unscrewed before the 6mm Allen Key can be
inserted to operate the hand crank.
Make sure there are no objects or persons on or
around the floor while hand cranking. Slowly
operate the actuator at the indicated speed and
torque.

SLIDE-OUT TROUBLESHOOTING

Error Condition Or Missing Operation Condition
When an error condition or a missing operation
condition is present on a slide- out, the green
indicator light on the corresponding control pad
starts blinking upon releasing of the IN/OUT
rocker switch.
Turning the ignition OFF and ON again, will stop
the blinking and reset the fault. If the error
condition or a missing operation condition is still
present, the blinking will start again the next time
that the slide-out is operated.
To initiate fault diagnostic, use the DID right after
operating the slide-out without cycling the ignition
switch.
NOTE
The DID is the main tool for troubleshooting a
multiplex vehicle. It is essential to have it in
working condition.
Fault Diagnostic
To get detailed information about the error
condition or the missing operation condition,
PA-1619 Owner's Manual H3-45 VIP