B-4 Multiplex Troubleshooting
Problem / Symptom
Entrance door does not
open nor close using the
control buttons
Defroster
fan
functioning
Windshield
wipers
functioning in speed 1 or
intermittent
Windshield
wipers
functioning in speed 1 or
intermittent
HVAC condenser fans
not functioning in speed 1
HVAC condenser fans
not functioning in speed 2
Windshield washer not
functioning
Windshield upper section
de- icing
system
functioning
Probable Causes
Module AE47 is not powered
or is faulty
not
not
not
No power on R27
Circuit breaker CB7 tripped
Circuit breaker CB7 tripped
Module AE44 is not powered
or is faulty
not
PA-1619 Owner's Manual H3-45 VIP
Actions
1. Check the DIAGNOSTICS menu of
Driver
Information
Select VIEW ACTIVE FAULTS and
ELECTRICAL.
Response ModA47, Active" indicates a
power problem on the module. (A DL0
(BBUS MUX) network problem would
show the same message but doesn't
produce these symptoms).
2. Check / reset circuit breaker CB1
3. Check / replace fuse F45
4. Probe gray connector on module to see
if it is powered.
5. Use the air release valves near the
entrance door and in the front service
compartment to lock / unlock the door
Check CB48 (VECF)
Check / reset circuit breaker CB7
Check / reset circuit breaker CB7
Check / replace fuse F135
1. Check the DIAGNOSTICS menu of
Driver
Information
Select VIEW ACTIVE FAULTS and
ELECTRICAL.
Response ModA44, Active" indicates a
power problem on the module. (A DL0
(BBUS MUX) network problem would
show the same message but doesn't
produce these symptoms).
2. Check / reset circuit breaker CB1
3. Check / replace fuse F44
4. Probe gray connector on module to see
if it is powered.
Display
(DID).
The
message
"No
Display
(DID).
The
message
"No