Schedule; Table 5-2 Preventative Maintenance Schedule - Will Burt Stiletto AL 4-Meter Operating Instructions Manual

Table of Contents

Advertisement

S
AL O
TILETTO
PERATING

5.4.1 Schedule

Table 5-2 provides a schedule of preventative maintenance inspections and procedures
required to keep the Mast System in good operating condition.
Frequency
Inspection
Keep Clean – Inspect to ensure the
As Needed
Mast System is kept clean and free
from foreign material. Dirt, grease,
(In salt water
oil, and debris may cover up a
environments,
serious problem.
clean the
mast at least
every three
months.)
Damage – Inspect for damage
During
Operation
before use. During extension and
retraction of the mast, inspect the
outer surfaces for damage.
Binding – During extension and
During
Operation
retraction of the mast, observe mast
operation for evidence of binding.
Damage – Inspect all visible
Weekly
surfaces for damage.
Finish – Inspect the condition of the
Weekly
mast finish. Look for bare metal, rust,
and corrosion.
Fasteners – Inspect external
Weekly
fasteners. Look for loose, missing,
bent, or broken fasteners. Look for
chipped paint, bare metal, or rust
around the bolt heads. Pay particular
attention to the fastener securing the
Mast System to the mounting
surface, the mast to the Drive
Assembly, the Motor to the Drive
Assembly, and the payload to the
mast.
5-4
I
NSTRUCTIONS

Table 5-2 Preventative Maintenance Schedule

Original Instructions
Action
Clean as you work and as needed.
Use denatured alcohol on all metal
surfaces. Use water when cleaning
rubber or plastic material. Use soap
and water when cleaning the exterior
surfaces of the mast tubes. Use a
soft, non-abrasive cloth to wipe clean
the bezel on the Universal Control
Box display.
If damage is apparent, do not use the
Mast System and have it serviced
before use.
Remove any foreign material or
obstructions as necessary.
If damage is apparent, do not use the
Mast System and have it serviced
before use.
Remove any rust or corrosion with a
wire brush. Touchup any bare metal
with touchup paint.
Replace any missing or damage
hardware. If any hardware is found
loose, retighten. If loose fasteners
joining major components cannot be
tightened, do not use the Mast
System and have it serviced before
use.
Continued