8.2.1 Error (Fault) Codes

Table 8-2 shows error (fault) codes that may appear on the Control Box Display. Reoccurrence
of error codes is possible if trigger conditions are met.
Error
Trigger
Code
Condition
System voltage
0001
drops below 17
VDC for 5
consecutive
seconds
0002
Control Box
detects 80 Amps
for more than 5
seconds
TP-5418901-F
August 2020

Table 8-2 Error (Fault) Codes

System Response
Excessive Low Volts
Fault (ERR 0001):
Disable all normal output
functions. If the
OVERRIDE Switch is
activated while this fault
is active,
re-enable all outputs.
CAUTION:
Avoid unnecessary
attempts to operate the
mast at excessive low
voltage levels to prevent
system damage.
NOTICE:
Even though outputs are
enabled, the mast may
not be able to move due
to the low system
voltage.
Excessive Motor
Current Fault
(ERR 0002):
Disable the Motor
Outputs.
Original Instructions
S
AL O
TILETTO
PERATING
Latch Until
• System is
• Excessive battery drain
above 18 volts
without sufficient charge
and no
current/time
Up/Down inputs
• Excessive Motor current
are active
due to mast resistance,
- or -
excessive payload, or
drive chain binding
• System power
• Insufficient power
is cycled and is
above 18 volts
supply
• Too long/undersized
power supply line
(mains)
• 5 OVERRIDE
• Excessive Motor current
Switch
due to mast resistance,
activations
excessive payload, or
within 3
drive system binding
seconds
- or -
• System power
is cycled and
trigger
conditions
cleared
I
NSTRUCTIONS
Possible Cause
Continued
8-5