Table 1-3 D-Tec Specifications - Will Burt Stiletto AL 4-Meter Operating Instructions Manual

Table of Contents

Advertisement

The D-TEC Features:
Two detection modes that operate simultaneously:
o Electric Field (E-Field) detection to sense the presence of nearby high voltage
AC
o Magnetic Field (H-Field) detection to sense the presence of nearby high current
AC
An LED Look-Up Light and an Ambient Light Sensor to ensure the Look-Up Light only
illuminates when it is dark
The D-TEC communicates over an RS-485 link with the Universal Control Box which
acts as the communications master. This means the Universal Control Box initiates all
communication. The D-TEC only allows or disallows the operator to extend the mast and
does not provide direct power to the mast. Both the D-TEC and the Universal Control
Box perform self-diagnostic routines each time the Mast System is powered up.
Specifications for the D-TEC are listed in Table 1-3.
Functional Characteristics
Detection
Minimum Voltage Detection
Look-Up Light
Input Voltage
Power Requirements
Operating Temperature Range
Duty Cycle
For more information on the D-TEC, see www.willburt.com.
TP-5418901-F
August 2020
S

Table 1-3 D-TEC Specifications

Operational Parameters
Simultaneous AC Voltage (Electric Field) and
Electromagnetic and Electrostatic (Magnetic
Field) Detection
2.3 Kilovolts/Meter at 0° (Reduced with angle)
LED
11 to 33 VDC
12 VDC 10 Amps or 24 VDC 5 Amps
-40°C to 71°C (-40°F to 160°F)
100%
Original Instructions
AL O
TILETTO
PERATING
I
NSTRUCTIONS
1-29