Error
Trigger
Code
Condition
0040
From Nested
position, Up
Switch active
for more than 2
seconds with no
Down limit
switch change
0080
From Fully
deployed
position, Down
Switch active
for more than 2
seconds with no
Up limit switch
change
0100
OVERRIDE
Switch has
been active for
an excessive
time period
0200
Up and Down
Limit Switches
are active at the
same time (not
physically
possible)
TP-5418901-F
August 2020
Table 7-2 Error (Fault) Codes Continued
System Response
Down Limit Switch
Failed/Stuck Fault
(ERR 0040):
Disable the Motor
Outputs unless the
OVERRIDE Switch is
also active.
Can occur on
combination with ERR
0001 or ERR 0002;
indicated as ERR 0041 or
ERR 0042.
Up Limit Switch
Failed/Stuck Fault
(ERR 0080):
Disable the Motor
Outputs unless the
OVERRIDE Switch is
also active.
Can occur on
combination with ERR
0001 or ERR 0002;
indicated as ERR 0081 or
ERR 0082.
Override Switch Stuck
Fault
(ERR 0100):
Ignore OVERRIDE
Switch input.
Note: This fault cannot be
overridden.
Conflicting Up/Down
Limit Switch Fault
(ERR 0200):
Disable the Motor
Outputs unless the
Override Switch is also
active
Original Instructions
S
AL O
TILETTO
PERATING
Latch Until
Possible Cause
• 5 OVERRIDE
• Switch requires
Switch
adjustment or
activations
recalibration
within 3
• Switch failed and
seconds
requires replacement
- or -
• Drive system damaged
• System power
is cycled and
trigger
conditions
cleared
• 5 OVERRIDE
• Switch requires
Switch
adjustment or
activations
recalibration
within 3
• Switch failed and
seconds
requires replacement
- or -
• Drive system damaged
• System power
is cycled and
trigger
conditions
cleared
• OVERRIDE
• Switch is being held on
Switch is no
• Switch is damaged
longer active
• Water ingress may be
- or -
activating switch input
• System power
is cycled and
trigger
conditions
cleared
• Either switch is
• Switch(es) require
no longer
adjustment or
active
recalibration
• Switch(es) failed and
- or -
require replacement(s)
• System power
• Cable or connection
is cycled and
trigger
failure
conditions