8.2.2 Warning Codes
Table 8-3 shows warning codes that may appear on the Universal Control Box Display.
Reoccurrence of warning codes is possible if trigger conditions are met.
Warning
Trigger
Code
Condition
0001
Both Up and
Down switches
detected
simultaneously.
(Local and
Remote
switches
conflict)
0002
System voltage
has dropped
below 20 VDC
for 5
consecutive
seconds.
(Remaining
above 18 VDC)
TP-5418901-F
August 2020
Table 8-3 Warning Codes
System Response
Conflicting Mast
Up/Mast Down
Switch Commands
Warning
(WRN 0001):
Disable the Motor
Outputs unless the
OVERRIDE Switch
is also active.
Low Volts Warning
(WRN 0002):
Allow all mast
normal functions.
Original Instructions
S
AL O
TILETTO
PERATING
Latch Until
Possible Cause
• One or both of
•
the conflicting
switch inputs
are no longer
•
active
- or -
• System power
•
is cycled and
trigger
conditions
•
cleared
• System
• Excessive battery
voltage
drain without
reaches 21
sufficient charge
VDC for 5
current/time
consecutive
• High Motor current
seconds.
due to mast
- or -
resistance or large
payload
• System power
is cycled and
trigger
conditions
cleared
I
NSTRUCTIONS
One or both
Switch(es) are
being held on
One or more
Switch(es) are
damaged
Water ingress
may be activating
switch input(s)
Cable or
connection failure
Continued
8-9