0010
Invalid (or no)
response from
Temperature
Sensor
0020
Pulses not
detected
during mast
positioning
TP-5418901-F
August 2020
Table 7-3 Warning Codes Continued
System Response
Temperature
Sensor Failure
Warning
(WRN 0010):
Allow all normal
mast functions
Pulse Counter
Warning (W0020):
Allow all normal
mast functions.
NOTICE:
Mast height readout
will be inaccurate.
Original Instructions
S
AL O
TILETTO
PERATING
Latch Until
Possible Cause
• Valid
• Temperature Sensor
temperature
failed and requires
reading
replacement
received
• Temperature Sensor
- or -
Wiring damaged and
requires repairs or
• 5 OVERRIDE
replacement
Switch
activations
within 3
seconds
- or –
• System power
is cycled and
trigger
conditions
cleared
• Valid pulse
• Pulse counter
count detected
requires adjustment
• 5 override
or recalibration
• Pulse counter failed
switch
activations
and requires
within 3
replacement
seconds
• Pulse counter wiring
• System power
damaged and
is cycled and
requires repairs or
trigger
replacement
conditions
cleared