Dimensions
Controllers
E5GC-@6
Controllers with Screw
Terminal Blocks
• Use two Mounting Adapters, either on the top and bottom or on the right and left.
• Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-
CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable
and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either
port connected constantly during operation.)
Mounted Separately
40 min
45
• To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed
adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.
• Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-
tain a balance, and tighten them to a torque of between 0.29 and 0.39 N·m.
• When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable
operating temperature range given below.
Horizontal group mounting: −10 to 55°C
• Use Temperature Controllers with Screwless Clamp Terminal Blocks for vertical group mounting.
E5GC-@C
Controllers with Screwless
Clamp Terminal Blocks
• Use two Mounting Adapters, either on the top and bottom or on the right and left.
• Setup Tool ports are provided as standard feature. Use these ports to connect a computer to the Digital Temperature Controller. The E58-
CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the side panel. The E58-CIFQ2 USB-Serial Conversion Cable
and E58-CIFQ2-E Communications Conversion Cable are required to connect to the port on the bottom panel. (You cannot leave either
port connected constantly during operation.)
Mounted Separately
40 min
45
• To install the Temperature Controller, insert it into a square hole in a panel with a thickness of 1 to 8 mm, and then insert the enclosed
adapter so that it locks into the grooves on the top and bottom or on the left and right of the rear case.
• Tighten the two mounting screws on the top and bottom or on the right and left of the Mounting Adapters alternately little by little to main-
tain a balance, and tighten them to a torque of between 0.29 and 0.39 N·m.
• When two or more Temperature Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable
operating temperature range given below.
Horizontal group mounting: −10 to 55°C
Vertical group mounting of two Controllers: −10 to 45°C
Vertical group mounting of three or more Controllers: −10 to 40°C
• If you use vertical group mounting, you cannot draw out the interior body of the Controller.
63.6
4
48
1
40.8
24
Horizontally Group Mounted
L1
+0.6
L1=(48×n-2.5)
0
n: Number of mounted Controllers (2 ≤ n ≤ 6)
+0.3
22.2
0
63.6
4
48
1
40.8
24
Horizontally Group Mounted
L1
+0.6
L1=(48×n-2.5)
0
n: Number of mounted Controllers (2 ≤ n ≤ 6)
+0.3
22.2
0
Waterproof Packing (Accessory, Y92S-P12 (also available for ordering separately))
Mounting Adapter (Accessory, Y92F-53 (also available for ordering separately))
Terminal Cover (Accessory, E53-COV27
(also available for ordering separately))
90
22
To mount the Temperature Controller so that it is waterproof,
+0.3
22.2
0
insert the Waterproof Packing onto the Temperature Controller.
Group mounting does not allow waterproofing.
+1.0
+0
Waterproof Packing (Accessory, Y92S-P12 (also available for ordering separately))
Mounting Adapter (Accessory, Y92F-53 (also available for ordering separately))
93
22
Vertically Group Mounted
+0.6
45
+0
+0.3
22.2
0
+1.0
+0
L2
+1.0
L2=(24×n-1.5)
+0
(Unit: mm)
44.8
22
44.8
22
To mount the Temperature Controller so
that it is waterproof, insert the Waterproof
Packing onto the Temperature Controller.
Group mounting does not allow waterproof-
ing.