E5CC-B (Push-In Plus Terminal Blocks)
Control output 1
Relay output
250 VAC, 3A
(resistive load)
Voltage output
Relay outputs
(for driving SSR)
outputs: 250 VAC, 2 A
12 VDC, 21 mA
(resistive load)
(1) Control output 1
RX
QX
Models with 1
Models with
Voltage Output
1 Relay Output
(for Driving SSR)
OUT1
1
1
+
R
−
2
2
(5) Sensor (Temperature/Analog) Input
TC
Pt
I
A
+
6
6
6
B
mA
-
7
7
7
B
-
8
8
8
+
(6) Options
002
001
Event Inputs 1
Communications
and 2, and CT1
(RS-485), CT1
(-)
B(+)
17
*
(-)
18
RS-485
19
EV1
A(-)
20
EV2
21
CT1
CT1
22
23
24
Note: 1. The application of the terminals depends on the model.
2. Do not wire the terminals that are shown with a gray background.
3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
4. Refer to Wiring Precautions for E5
methods.
5. Common terminals are indicated with asterisks (*). You can use the input power supply and communications common terminals for
crossover wiring. Do not exceed the maximum number of Temperature Controllers given below if you use crossover wiring for the input
power supply.
100 to 240 VAC Controllers: 16 max.
24 VAC/VDC Controllers: 8 max.
Wiring Example:
To another E5@C
6. Due to UL Listing requirements, use the E54-CT1L or E54-CT3L Current Transformer with the factory wiring (internal wiring). Use a UL
category XOBA or XOBA7 current transformer that is UL Listed for field wiring (external wiring) and not the factory wiring (internal wiring).
E5CC-@@ 2 @ B M - @ @ @
Auxiliary outputs 1, 2
The E5CC is set for a K-type thermocouple
(input type = 5) by default. An input error
(s.err) will occur if the input type setting does
not agree with the temperature sensor. Check
the input type.
CX
Models with 1
Linear Current Output
OUT1
OUT1
1
+
Q
C
−
2
V
6
-
7
V
8
+
004
Communications
(RS-485), and
Event Inputs 3 and 4
B(+)
17
17
*
18
RS-485
18
19
19
A(-)
*
20
20
(-)
21
21
(-)
22
22
23
23
EV3
24
24
EV4
Use no-voltage inputs for the event inputs.
The polarity for non-contact inputs is given in parentheses.
@
C-B (Controllers with Push-In Plus Terminal Blocks) on page 133 for wire specifications and wiring
13
14
15
16
(1) (2) (3) (4) (5)
(6)
↑
Terminal type
1
17
9
2
18
10
3
19
11
4
20
12
5
21
13
6
22
14
7
23
15
8
24
16
006
Event Inputs
1 and 2, and
Transfer Output
(-)
17
*
*
(-)
18
19
EV1
*
20
EV2
21
*
+
22
+
V
Transfer
23
I
Output
24
-
E5CC/E5CC-B/E5CC-U
(2) Auxiliary Outputs
9
Auxiliary output 2
10
11
Auxiliary output 1
12
(3) Input Power Supply
100 to 240 VAC
24 VAC/DC
13
13
*
14
14
15
15
*
16
16
(no polarity)
*
*
*
31