60 MAINTENANCE STANDARD
No.
Item
1
Centering spring
2
Metering spring
Tightening torque of the
3
bolt
PC500LC-10R
MAINTENANCE STANDARD OF 1ST-LINE ATTACHMENT PPC VALVE
Judgment criteria
Standard dimensions
Free height
Installed
x outside
height
diameter
33.9 x 15.3
28.4
22.7 x 8.10
22.0
11.76 to 14.7 Nm {1.2 to 1.5 kgm} 
Repair limit
Load at in-
stalled
Free height
height
125 N 
-
{12.7 kg} 
16.7 N 
-
{1.70 kg} 
(WITH EPC VALVE)
Unit:  mm
Remedy
Load at in-
stalled
Replace the
height
spring if dam-
aged or de-
100 N 
formed
{10.2 kg} 
13.3 N 
{1.36 kg} 
Re-tighten
60-57