Komatsu PC500LC-10R Shop Manual page 564

Hydraulic excavator
Table of Contents

Advertisement

SET AND OPERATE MACHINE MONITOR
1.
Select "Adjustment" on "Service Menu" screen.
REMARK
For selecting method, see "METHOD FOR OPERATING
SERVICE MODE" in "SERVICE MODE".
2.
On the "Adjustment" screen, select "Att Flow Adjust in
Combined Ope" with function switches or numeral input
switches.
REMARK
For selecting method, see "METHOD FOR OPERATING
SERVICE MODE" in "SERVICE MODE".
3.
Select the set value on the right side by using the function
switches on "Att Flow Adjust in Combined Ope" screen.
See the table for flow distribution.
F3: Set value decreases.
F4: Set value increases.
F6: Setting is confirmed or entered. The screen returns to
"Adjustment" screen.
REMARK
The 3-digit number in the left column does not change.
This is the code for this function.
Relationship between the set value and distribution of oil flow to attachment
Code
037
METHOD FOR ADJUSTING (Fan Rotation Mode Selection)
Use the adjustment menu to check the various settings of the machine or to adjust the value.
The Fan Rotation Mode Selection is used to select the maximum speed of the cooling fan from the normal con-
trol mode, 100 % mode or 70 % mode.
30-158
Set value
000
001
002
003
30 TESTING AND ADJUSTING
Distribution of flow to attachment
50 %
70 %
100 %
40 %
PC500LC-10R

Advertisement

Table of Contents
loading