STANDARD VALUE TABLE FOR MACHINE: PC500LC-10R
Traveling
Item
Engine speed
(idle running)
Travel speed
(actual running)
Travel deviation
20-20
Machine model
Engine
Measurement condition
Hydraulic oil temper-
Lo
ature: 45 to 55 °C
Mi
Fuel control dial:
MAX (High idle) po-
sition
Working mode: P
(Power Mode)
Time required to
complete 5 idle turns
of track off the
Hi
ground after 1 idle
turn
Measuring posture:
See "Machine pos-
ture and procedure
for measuring per-
formance", "Fig. 4".
Hydraulic oil temper-
Lo
ature: 45 to 55 °C
Mi
Fuel control dial:
MAX (High idle) po-
sition
Working mode: P
(Power Mode)
Time required for
traveling 20 m after
Hi
running up 10m on a
flat ground
Measuring posture:
See "Machine pos-
ture and procedure
for measuring per-
formance", "Fig. 5".
Hydraulic oil temperature: 45 to
55 °C
Fuel control dial: MAX (High idle)
position
Working mode: P (Power Mode)
Travel speed: Lo
Travel deviation (x) in travel of 20m
after running up 10m on a firm and
flat ground
Measuring posture: See "Machine
posture and procedure for measur-
ing performance", "Fig. 5" and "Fig.
6".
20 STANDARD VALUE TABLE
PC500LC-10R
SAA6D125E-5
Standard value for
Unit
new machine
67.3±13.5
48.1±7.2
 sec
36.7±3.6
24.0±4.8
17.1±2.6
 sec
13.1±1.3
 mm
200 or less
Repair limit
45.0 to 84.5
34.0 to 58.0
32.0 to 44.0
18.9 to 31.0
14.4 to 21.0
11.7 to 15.1
300 or less
PC500LC-10R

Advertisement

Table of Contents
loading

Table of Contents