Komatsu PC500LC-10R Shop Manual page 547

Hydraulic excavator
Table of Contents

Advertisement

30 TESTING AND ADJUSTING
4.
Select "Maintenance Notice Time Setting". Set the notice
time with the function switches on the "Maintenance Notice
Time Setting" screen.
Default value: Maintenance notice time set on the machine
monitor (Recommended by the manufacturer and not
changeable).
Set value: Maintenance notice time can be arbitrarily set.
Maintenance reminder function works according to this
set time in operator mode (the time can be increased or
decreased in 10-hour unit).
F3: Decreases the value.
F4: Increases the value.
F5: Set value is canceled. The screen returns to "Mainte-
nance Mode Setting" screen.
F6: Enters the set value. The screen returns to the "Main-
tenance Mode Setting" screen.
REMARK
• Press F6 to enter the setting. The screen returns to the
"Maintenance Mode Setting", and the setting is ena-
bled.
• If the setting item is changed when the maintenance
mode setting is turned "ON" after running the machine
more than an hour from the setup, the change is recog-
nized as a reset operation.
5.
Select one of the maintenance items. When the individual
maintenance item screen is displayed, select "On or Off
Setting".
F3: Moves the selection downward.
F4: Moves the selection upward.
F5: Selection is canceled. The screen returns to "Mainte-
nance Mode Change" screen.
F6: Enters the selected item. The individual maintenance
item moves to the screen to "ON", "ON (Breaker Syn-
chronization)", and "OFF" screen.
REMARK
• The screen shown is "Additional Hydraulic Oil Filter Change Interval" as an example.
• If "ON (Breaker Synchronization)" is selected, "B ON" is shown on "On or Off Setting".
6.
On the individual maintenance item screen, select either
"ON" or "ON (Breaker Synchronization)" or "OFF" with a
function switch.
"ON": Enables the function of the individual maintenance
item in "operator mode".
"ON (Breaker Synchronization)": Enables the function of
the individual maintenance item in "OPERATOR MODE".
Maintenance remaining time is reduced at an accelerat-
ed rate according to the breaker use remaining time.
"OFF": Disables the function of the individual maintenance
item in operator mode.
F3: Moves the selection downward.
F4: Moves the selection upward.
PC500LC-10R
SET AND OPERATE MACHINE MONITOR
30-141

Advertisement

Table of Contents
loading