10 STRUCTURE AND FUNCTION
COMPONENT PARTS OF HYDRAULIC SYSTEM
When cylinder head pressure is lower than bottom pressure
Check valve (6) installed to regeneration circuit (C) closes to cut the oil flow from the cylinder head to the cylin-
der bottom.
PC500LC-10R
10-161