Komatsu PC500LC-10R Shop Manual page 593

Hydraulic excavator
Table of Contents

Advertisement

30 TESTING AND ADJUSTING
Item
Engine coolant temperature: 60
to 100 °C
Hydraulic oil temperature: 45 to
Engine
speed when
55 °C
oil pressure
Fuel control dial: MAX (High
of 2 pumps
idle) position
are relieved
Working mode: P (Power
+ One-touch
Mode)
power maxi-
mizing is ac-
Work equipment: Relieve the
tuated (*1)
oil pressure in arm IN circuit +
One-touch power maximizing is
actuated
Engine coolant temperature: 60
to 100 °C
Hydraulic oil temperature: 45 to
55 °C
Engine
speed when
Fuel control dial: MAX (High
auto-decel-
idle) position
eration is
Working mode: P (Power
actuated
Mode)
(*1)
Swing lock switch: OFF
All control levers and control
pedals in NEUTRAL position
Engine coolant temperature: 60
to 100 °C
Working mode: P (Power
Mode)
Fuel control dial: MAX (High
idle) position
Engine oil
All control levers and control
pressure
pedals in NEUTRAL position
Engine oil (*2)
EOS0W30
EOS5W40
EO10W30-DH
EO15W40-DH
PC500LC-10R
Machine model
Engine
Testing conditions
PC500LC-10R
SAA6D125E-5
Standard val-
Unit
ue for new
machine
 rpm
1620 to 1820
 rpm
900 to 1100
 MPa
0.29 to 0.69
2
{3.0 to 7.0}
{ kg/cm
}
Pm CLINIC SERVICE
Meas-
Repair limit
ured val-
ue
1620 to 1820
900 to 1100
0.18 or more
{1.8 or more}
No
Goo
goo
d
d
30-187

Advertisement

Table of Contents
loading

Table of Contents