SET AND OPERATE MACHINE MONITOR
F5: Selection is canceled. The screen returns to the selected maintenance item.
F6: Enters the selection. The screen returns to the selected maintenance item.
REMARK
You can select "ON (Breaker Synchronization)" for items that varies with the breaker use remaining time.
Items that ON (Breaker Synchronization) can be selected for
Code
68
Additional Hydraulic Oil Filter Change Interval
30
Hydraulic Oil Pilot Filter Change Interval
04
Hydraulic Oil Filter Change Interval
10
Hydraulic Oil Change Interval
7.
Select "Set" of each maintenance item. When the screen
of each maintenance item is displayed, perform the setting
with the function switches.
Default value: Maintenance notice time set on the machine
monitor (Recommended by the manufacturer and not
changeable).
Set value: Maintenance notice time that is arbitrarily set.
Maintenance reminder function works according to this
set time in operator mode (the time can be increased or
decreased in multiples of 25).
F3: Decreases the value.
F4: Increases the value.
F5: Set value is canceled. The screen returns to "Mainte-
nance Mode Change" screen.
F6: Enters the set value. The screen returns to "Mainte-
nance Mode Change" screen.
REMARK
• Press F6 to enter the setting. The screen returns to the
"Maintenance Mode Setting", and the setting is ena-
bled.
• If the setting item is changed when the maintenance
mode setting is turned "ON" after running the machine
more than an hour from the setup, the change is recog-
nized as a reset operation.