Komatsu PC500LC-10R Shop Manual page 557

Hydraulic excavator
Table of Contents

Advertisement

30 TESTING AND ADJUSTING
4.
On "With/Without Eco mode Easy Setting" screen, select a
setting with the function switch.
Without: Eco mode Easy Setting is disabled
With: Eco mode Easy Setting is enabled
F3: Moves the selection downward.
F4: Moves the selection upward.
F5: The screen returns to the "Option" screen
F6: Selection is entered. The screen returns to "Option"
screen
METHOD FOR SETTING WITH DEFAULT SETTING MENU (With/Without Water in
Fuel Sensor)
Default setting menu is used to check or change default values of the machine monitor and the machine.
For setting With/Without of WIF sensor, refer to this section.
1.
Select "Default" on "Service Menu" screen.
REMARK
See "METHOD FOR OPERATING SERVICE MODE" in
"SERVICE MODE" for selecting method.
2.
Select "Option" with the function switches or numeral input
switches on "Default" screen.
REMARK
See "METHOD FOR OPERATING SERVICE MODE" in
"SERVICE MODE" for selecting method.
3.
Select "With/Without Water in Fuel Sensor" with the func-
tion switches or numeral input switches on "Option"
screen.
REMARK
See "METHOD FOR OPERATING SERVICE MODE" in
"SERVICE MODE" for selecting method.
PC500LC-10R
SET AND OPERATE MACHINE MONITOR
30-151

Advertisement

Table of Contents
loading

Table of Contents