10 STRUCTURE AND FUNCTION
•
In B mode or L mode, engine output is kept constant.
•
The controller controls pump absorption upper limit torque
(PT) so that the engine torque is kept constant along the
equal engine horsepower curve.
PC500LC-10R
ENGINE AND PUMP COMBINED CONTROL SYSTEM
10-99