Komatsu PC500LC-10R Shop Manual page 596

Hydraulic excavator
Table of Contents

Advertisement

Pm CLINIC SERVICE
Item
Hydraulic oil temperature: 45 to
55 °C
Fuel control dial: MAX (High
idle) position
Working mode: P (Power
Mode)
Measurement range: Between
arm IN stroke end and arm
Arm OUT
OUT stroke end
Measurement posture: Boom
top face horizontal
See the STANDARD VALUE
TABLE, "MACHINE POSTURE
AND PROCEDURE FOR
MEASURING PERFORM-
ANCE", "Work equipment 3".
Hydraulic oil temperature: 45 to
55 °C
Fuel control dial: MAX (High
idle) position
Working mode: P (Power
Mode)
Measurement range: Between
bucket DUMP stroke end and
Bucket
bucket CURL stroke end
CURL
Measurement posture: Boom
top face horizontal, fully retract-
ed arm cylinder
See the STANDARD VALUE
TABLE, "MACHINE POSTURE
AND PROCEDURE FOR
MEASURING PERFORM-
ANCE", "Work equipment 3".
30-190
Machine model
Engine
Testing conditions
PC500LC-10R
SAA6D125E-5
Standard val-
Unit
ue for new
machine
 sec
3.3 to 4.1
 sec
3.1 to 3.9
30 TESTING AND ADJUSTING
Meas-
Repair limit
ured val-
ue
4.4 or less
4.2 or less
PC500LC-10R
No
Goo
goo