Komatsu PC500LC-10R Shop Manual page 391

Hydraulic excavator
Table of Contents

Advertisement

20 STANDARD VALUE TABLE
Operating effort of control lever and pedal
Item
Boom control
lever
Arm control lever
Bucket control
lever
Swing control
lever
Travel control
lever
Travel control
pedal
Work equipment, Swing, and Travel oil pressure
Item
Unload pressure
PC500LC-10R
Machine model
Engine
Measurement condition
Hydraulic oil temperature: 45 to
55 °C
Fuel control dial: MAX (High idle)
position
Control lever: At center of grip
Pedal: At tip of pedal
Read the maximum value when the
lever is operated to the stroke end
Machine model
Engine
Measurement condition
Hydraulic oil temperature: 45 to 55 °C
Fuel control dial: MAX (High idle) posi-
tion
Working mode: P (Power Mode)
Auto-deceleration switch: OFF
All control levers and control pedals in
NEUTRAL position
STANDARD VALUE TABLE FOR MACHINE: PC500LC-10R
Standard value for
Unit
 N
{ kg}
Unit
 MPa
2
{ kg/cm
}
PC500LC-10R
SAA6D125E-5
Repair limit
new machine
15.7±3.9
24.5 or less
{1.6±0.4}
{2.5 or less}
15.7±3.9
24.5 or less
{1.6±0.4}
{2.5 or less}
12.7±2.9
21.6 or less
{1.3±0.3}
{2.2 or less}
12.7±2.9
21.6 or less
{1.3±0.3}
{2.2 or less}
24.5±5.9
39.2 or less
{2.5±0.6}
{4.0 or less}
74.5±18.6
107.6 or less
{7.6±1.9}
{11 or less}
PC500LC-10R
SAA6D125E-5
Standard value
Repair limit
for new machine
4.2±1.0
{42±10}
4.2±1.0
{42±10}
20-15

Advertisement

Table of Contents
loading

Table of Contents