SET AND OPERATE MACHINE MONITOR
•
Selection with function switches: Select an applicable equipment by using F1 or F2, select an item by
using F3 or F4, and then enter it by using F6.
•
For the selected item with numeral input switches, enter a 5-digit code, and the item of that code is
selected directly, and then enter it with F6.
•
If the color of the selected box changes from yellow to red, the selected item has been entered.
•
Up to six monitoring items are selectable at a time. However, the items may not be set up to six de-
pending on the form of display of the selected item.
3.
After monitoring items are selected, execute the monitor-
ing with the function switches or numeral input switches.
•
When you use the function switch, double-click the F6
switch or hold it down. (Approximately 2 seconds)
•
Execution with the numeral input switches: Input
"99999" and press F6.
•
If monitoring items are selected up to the limit number,
monitoring is executed automatically.
REMARK
When performing the monitoring of only 2 items, select
each item, and confirm them with F6. If F6 is pressed once
again, monitoring is executed.
4.
Perform the necessary operation of the machine and
check the self-define monitoring information on "Monitor-
ing" screen.
REMARK
• Monitoring information is indicated by value, ON/OFF,
or special display.
• The display unit can be set to "SI", "Metric", or "Imperi-
al" with "Default" function.
5.
Hold the monitoring information or cancelling HOLD can
be performed with the function switches.
F4: Selects HOLD or releasing HOLD. (When HOLD is se-
lected, "HOLD" part is hatched.)
F5: The screen returns to "Monitoring Selection Menu"
screen.
30-126
30 TESTING AND ADJUSTING
PC500LC-10R