SET AND OPERATE MACHINE MONITOR
Selection with function switches: Select an applicable equipment by using F1 or F2, select an item by
using F3 or F4, and then enter it by using F6.
For the selected item with numeral input switches, enter a 5-digit code, and the item of that code is
selected directly, and then enter it with F6.
If the color of the selected box changes from yellow to red, the selected item has been entered.
Up to six monitoring items are selectable at a time. However, the items may not be set up to six de-
pending on the form of display of the selected item.
3.
After monitoring items are selected, execute the monitor-
ing with the function switches or numeral input switches.
When you use the function switch, double-click the F6
switch or hold it down. (Approximately 2 seconds)
Execution with the numeral input switches: Input
"99999" and press F6.
If monitoring items are selected up to the limit number,
monitoring is executed automatically.
REMARK
When performing the monitoring of only 2 items, select
each item, and confirm them with F6. If F6 is pressed once
again, monitoring is executed.
4.
Perform the necessary operation of the machine and
check the self-define monitoring information on "Monitor-
ing" screen.
REMARK
• Monitoring information is indicated by value, ON/OFF,
or special display.
• The display unit can be set to "SI", "Metric", or "Imperi-
al" with "Default" function.
5.
Hold the monitoring information or cancelling HOLD can
be performed with the function switches.
F4: Selects HOLD or releasing HOLD. (When HOLD is se-
lected, "HOLD" part is hatched.)
F5: The screen returns to "Monitoring Selection Menu"
screen.
30-126
30 TESTING AND ADJUSTING
PC500LC-10R