Table 080-31: Service Programming Mode, G 283X/G 2872 - Miele G 1 Series Technical Information

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

Technical Information
Function
Resetting standard
settings
Adjusting the main wash
temperature
Water quantity
normal/increased
Activating/deactivating
sensor softener, manually
setting water hardness
Program running
time reduction
(G 2830 only)
Second interim rinse
SC (with or without
cutlery tray) - available
for ID no. -1856
Machine height setting
Country setting
Model setting
(G 2872 only)

Table 080-31: Service Programming Mode, G 283x/G 2872

1
This parameter can also be modified by the customer in the Settings menu under
External Water Softeners. See the appropriate operating/installation instructions.
2
If the electronic needs to be replaced during servicing, then the following steps must be
taken during programming: Set the country variant, then switch off the machine. Access
the programming mode again and set the machine height.
3
The SER variant includes the following countries: Portugal, France, the Netherlands,
Belgium and Great Britain.
Save and quit:
Switch off the appliance.
Programming
Select Factory default.
To reset the parameters
(settings) modified by the
customer to their standard
settings, confirm with OK.
Select Temperature.
Select Main wash or Final
rinse (G 2830 only).
Select a setting and
confirm with OK.
Select Water plus. Select
a setting; confirm with OK.
Select Water hardness.
Select a setting; confirm
1
with OK.
Select Shorten the
program. Make the
desired selection and
confirm with OK.
Select 2nd interim rinse.
Select a setting and
confirm with OK.
Select SC. Make the
desired selection and
confirm with OK.
Select Machine height.
2
Select a setting and
confirm with OK.
Select Country version.
2
Select a setting and
confirm with OK.
Select Model version.
2
Select a setting and
confirm with OK.
206
G 1xxx/G 2xxx
Display
The display reads Reset to
standard settings?
Options: Normal and Increased.
Increased wash temperature results
in a longer running time.
Options: Normal and Increased. If
Increased is selected, water intake
increases by 16.7 fl.oz. (500mL).
Auto = Sensor softener activated.
The water hardness at the
installation site can also be
manually set. Water hardness
range: 1°d to 70°d (1.1 to 74.9 gpg).
See Section 080-4.2.14.
The display shows the options On
and Off (standard setting).
Program-dependent running time is
reduced by reducing temperatures
and/or canceling holding times.
Options: On, Off (standard setting).
Options On, Off.
Programming function not available
at this time.
Options: Normal (G 1xxx), XXL (G
2xxx).
Setting options: EUR (Europe),
AUS (Australia), USA, JPN (Japan),
I/E (Italy/Spain), SER (S. Europe).
Options: 0 = Models w/salt con-
tainer in door: G x772, G x872; 1 =
Models w/salt container in sump: G
x672.
3

Advertisement

Table of Contents
loading

Table of Contents