G 1xxx/G 2xxx
3.8

Fault Code Summary

Note:
Not all fault codes apply to all model numbers.
Fault Code
F00
F01 (see Section 080-3.11)
F02 (see Section 080-3.12)
F11 (see Section 080-3.13)
F12 (see Section 080-3.14)
F13 (see Section 080-3.15)
F14 (see Section 080-3.16)
F15 (see Section 080-3.17)
F18 (see Section 080-3.18)
F19 (see Section 080-3.19)
F24 (see Section 080-3.20)
F25 (see Section 080-3.21)
F26 (see Section 080-3.22)
F32 (see Section 080-3.23)
F33 (see Section 080-3.24)
F36 (see Section 080-3.25)
F40 (see Section 080-3.26)
F42 (see Section 080-3.27)
F47 (see Section 080-3.28)
F51 (see Section 080-3.29)
F52 (see Section 080-3.30)
F53 (see Section 080-3.31)
F63 (see Section 080-3.32)
F67 (see Section 080-3.33)
F68 (see Section 080-3.34)
F69 (see Section 080-3.35)
F70 (see Section 080-3.36)
F78 (see Section 080-3.37)
F79 (see Section 080-3.38)
F84 (see Section 080-3.39)
F85 (see Section 080-3.40)
F86 (see Section 080-3.41)
F87 (see Section 080-3.42)
F88 (see Section 080-3.43)
F91 (see Section 080-3.44)

Table 080-2: Fault Code Summary

Possible Fault
No fault registered
Water/heating NTC or leads short-circuited
Water/heating NTC or leads open-circuited
Drainage fault
Water intake fault at start of step
Water intake fault at end of step
Water intake fault: Heater pressure switch
Water intake fault: Hot water
Flow meter stationary state monitor
Flow meter stiff and not turning freely
Heater relay contact
Target temperature fault
Boiling protection
Door lock does not close
Door lock does not open
Door lock switch defective
Electronic fault
Line frequency registration fault
Faulty electronic interface (between BAE & SLT)
Heater pressure switch
Heater pressure switch has reset during heating
Speed sensor fault
Slide shutter fault
Circulation pump speed too low
Circulation pump operating after switch-off
Circulation pump blocked
Float switch fault
Circulation pump fault
Circulation pump interaction fault
Slide shutter positioning fault
Slide shutter signal change fault
Lid contact - salt
Sensor softener fault
Turbidity sensor fault
Load size registration inactive