Miele G 1 Series Technical Information page 194

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

Technical Information
Function
Softener sensor activation/
Water hardness setting
Dispensed rinse aid
quantity setting
Adjust Sensor Wash
program (ID nos. -984 and
1
later)
Resetting standard
settings
Adjusting the main wash
temperature
(ID nos. -984 and later)
Programming
Press the Delay Start
button 2x. The "Delay
Start" LED flashes 2x
quickly intermittently.
1
Press the Start/Stop
button as appropriate to
make the desired setting.
Press the Delay Start
button 3x. The "Delay
Start" LED flashes 3x
quickly intermittently.
Press the Start/Stop
button as appropriate to
make the desired setting.
Press the Delay Start
button 5x. The "Delay
Start" LED flashes 5x
quickly intermittently.
Press the Start/Stop
button as appropriate to
make the desired setting.
Press the Delay Start
button 12x. The "Delay
Start" LED flashes once
slowly and 2x quickly
intermittently. Press the
Start/Stop button to reset
all standard settings.
Press the Delay Start
button 20x. The "Delay
Start" LED flashes 2x
slowly intermittently. Press
the Start/Stop button as
appropriate to make the
desired setting.
194
G 1xxx/G 2xxx
Display
The "Rinse" LED is out or flashes.
The display shows p and the digit/s
of the set value alternately. p0 =
Softener sensor active. Hardness
setting range: p1 to p70; see Table
080-28.
The "Rinse" LED is out or flashes.
The display shows P and a digit
alternately: e.g., P3 (standard
setting) indicates a dispensed
quantity of 0.1 fl.oz. (3mL). Setting
range: 0 - 0.2 fl.oz. (0 - 6 mL).
The "Rinse" LED is out or flashes.
The display shows P and a digit
alternately. Setting options: P0 =
Standard program cycle (factory
setting); P1 = Adjusted program
cycle. The Sensor Wash program
can be adjusted in this parameter to
deal with stubborn soiling (if
otherwise low overall soiling). If this
option is selected, the main wash
temperature is increased to 131°F
and, as a result, the program
duration is extended.
The "Rinse" LED is out or flashes.
This programmable function can be
used to reset all customer-modified
parameters back to their standard
settings. The display shows P and a
digit alternately. P0 = Settings have
been modified; P1 = All settings reset
to standard settings or no
modifications have been made.
The "Rinse" LED is out or flashes.
The display shows p and a digit
alternately. Setting options: p0 =
Standard setting; p1 = Wash
temperature increased. If this option
is selected, the main wash
temperature is increased and, as a
result, the program duration is
extended.

Advertisement

Table of Contents
loading

Table of Contents