3.3.4.1

Braking chopper unit

A BCU is used when the braking scenario requires consistent energy
dissipation. The energy generated during braking is dissipated in external
water-cooled resistors, which are not part of the drive.
(1) Resistor (external)
(1) IGCT
3BHS212794 E01 REV M
2
1
Figure 3-26 BCU circuit diagram
Figure 3-27 BCU cabinet
ACS6000 USER MANUAL
03 POWER ELECTRONICS AND CABINET FEATURES
DC (+)
DC (NP)
DC (-)
(2) BCU
1