AC busbars between COU/TEU and LSU (5/7/9 MVA)

The busbar configuration shown in Fig. 5-7 is for a TEU (A) connected to
the left side of an LSU (B). For a TEU connected to the right side of an LSU,
the busbar configuration is the mirror image of this figure.
A
Figure 5-7 AC busbar joints between the COU/TEU and LSU (5/7/9 MVA).
Item
(1) Connection bus bar
(2) Connection bus bar
(3) Connection bus bar
(4) Bus bar spacer
(5) Hex-head bolt
(6) Hex-head bolt
(7) Conical spring
washer
(8) Hex-head nut
(9) Flange nut
3BHS212794 E01 REV M
1
B
2
3
4
5
6
Quantity Technical
parameters
1
LSU-TEU 1b
1
LSU-TEU 2b
4
LSU-TEU 3b
4
80 mm spacer 10 mm 3BHB031095R0001
32
M12 x 45-A2-70
16
M12 x 50-A2-70
80
DIN6796-13 x 29 x 3
32
M12-A2-70
16
M12-A2
ACS6000 USER MANUAL
05 MECHANICAL INSTALLATION
8
7
5
9
4
8
6
5
7
Identification
3BHB045554R0001
3BHB045556R0001
3BHB045558R0001
NB 312450P8120
NB 312450P8121
HAQN400344P0111
HZN 452198P1022
3BHB038117R0001
107/278