Dcs800 Converter; Com-8X Circuit Board (A) In A Dcs800 Converter - ABB ACS6000 User Manual

System drives
Hide thumbs Also See for ACS6000:
Table of Contents

Advertisement

6.8.7.3
Routing optical fiber cables in an EXU cabinet with an ED5V, EB5R, EB5S, EB7P
or EB7Q type DCS800 converter
1. Remove the acrylic protection cover in the cabinet.
2. Unplug the DCS800 control panel.
Figure 6-37 DCS800 converter (ED5V, EB5R, EB5S, EB7P and EB7Q types)
(1) Control panel
(2) Indentation
3. Insert a flat-blade screwdriver into one of the indentations at the
bottom of the removable cover.
4. Gently press down the latch tab with the tip of the screwdriver and
pull the corner of the cover forward and repeat for the other side.
5. Slide the removable cover up and then remove the cover.
6. Connect the 2 optical fibers to the receptacles of channel CH0 (B) on
the COM-8x circuit board (A) according to the terminal numbers
printed on the marker sleeves.
Figure 6-38 COM-8x circuit board (A) in a DCS800 converter (ED5V, EB5R and
3BHS212794 E01 REV M
1
2
A
EB5S types) and a detail of channel CH0 (B) on the board.
(3) Removable cover
(4) Location of COM8x circuit board
ACS6000 USER MANUAL
06 ELECTRICAL INSTALLATION
3
4
2
B
CH0
160/278