The control system is configured, customized and tuned with a set of
application parameters. The application parameters are organized in
functional groups and have factory-set default values. The default
parameter values are set during commissioning to the specific application
of the drive. The settings activate the specific control, monitoring and
protection functions for the driven process, and define the signals and
data transferred between drive and external equipment.
Note: For more information on the parameters, see the "Appendix G –
Signal and parameter table".
3.2.5.3

AMC circuit board

The AMC circuit board is the major component of the control system and
performs general drive, motor control, and closed loop functions. The
main internal control hardware and the peripheral input and output
interfaces to the customer communicate with the AMC circuit board via
optical fibers.
The circuit board is fitted with a Motorola DSP processor and features two
PPCS and eight DDCS communication channels. The communication
channels are used for high-speed data transfer to the INT circuit boards
inside the ARU and INU (Fig. 3-12).
A
Figure 3-13 Examples of AMC circuit boards in 1000 mm COU (A) and
(1) AMC circuit board
3BHS212794 E01 REV M
03 POWER ELECTRONICS AND CABINET FEATURES
1
1
600 mm COU (B)
ACS6000 USER MANUAL