Preparing The Mounting Cutout - Siemens SIMATIC KP400 Comfort Operating Instructions Manual

Hmi devices comfort panels
Table of Contents

Advertisement

3.1.5

Preparing the mounting cutout

NOTICE
Stability of the mounting cutout
The material in the area of the mounting cutout must provide sufficient strength to
guarantee the enduring and safe mounting of the HMI device.
The force of the clamps or operation of the device may not lead to deformation of the
material in order to achieve the degrees of protection described below.
Degrees of protection
The degrees of protection of the HMI device can only be guaranteed if the following
requirements are met:
● Material thickness at the mounting cutout for a protection rating of IP65 or Front face
● Permitted deviation from plane at the mounting cutout: ≤ 0.5 mm
● Permissible surface roughness in the area of the seal: ≤ 120 µm (R
Compatibility of the mounting cutout to other HMI devices
The mounting cutouts of the following HMI devices are compatible with the mounting cutouts
of the following predecessor devices:
HMI device
KP400 Comfort
KTP400 Comfort
KP700 Comfort
TP700 Comfort
KP900 Comfort
KP1500 Comfort
Please note that although the dimensions for the mounting cut-out are the same, the device
depth and/or the enclosure front dimensions may differ from the respective dimensions of the
predecessor devices.
Comfort Panels
Operating Instructions, 03/2012, A5E03404994-02
only Type 4X/Type 12 (indoor use only): 2 mm to 6 mm
This condition must be fulfilled for the mounted HMI device.
Mounting and connecting the HMI device
Mounting cutout compatible to
OP 77B
TP 177B 4"
OP 277 6"
TP 177B 6", MP 177 6", TP 277 6"
MP 277 8" key
MP 377 12" key
3.1 Preparation for mounting
120)
z
33