Digital and Analog NCK I/Os (A4)
NCK I/O via PLC
Analog NCK input without hardware
The following values are read in the case of parts-program access to analog NCK inputs that
are defined via machine data, but are not available as hardware inputs:
MD10300 $MN_FASTIO_ANA_NUM_INPUTS
● The setpoint set by the PLC,
● Otherwise 0 volts
This makes it possible to use the functionality of the analog NCK inputs from the PLC user
program without I/O hardware.
Applications
The analog NCK inputs are used particularly for grinding and laser machines (e.g. for the
"analog calipers" NC function).
42
if the IS "PLC setting value for analog NCK inputs"
is set to "1" (see fig.).
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Extended Functions