Structure Of The Configuration File - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

2.2.4

Structure of the configuration file

The structure of the configuration file NETNAMES.INI is as follows:
Figure 2-12
In the following tables,
● Parameters which the user may need to change are printed in
● Parameters which can be used as alternatives are specified separated by |.
I. HMI identification
PCU/HT6 identifier to which NETNAMES.INI applies:
Element
[own]
owner =
II. PCU/HT6 NCU connections
Configuring the connections between PCU/HT6 and the NCUs:
Element
[conn
conn_i =
Extended Functions
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Several Operator Panels on Several NCUs, Distributed Systems (B3)
Several operator panel fronts and NCUs with control unit management option
Structure of the configuration file NETNAMES.INI
Identifier
Identifier
]
NCU_ID
Explanation
Header
HMI identification
Explanation
Header
Configuring the NCU
connection(s)
i = 1, ..., 15
italics
Example
[own]
owner = MMC_1
Example
[conn MMC_1]
conn_1 = NCU_1
conn_2 = NCU_2
...
conn_i = NCU_i
109