Siemens SINUMERIK 840D sl Function Manual page 840

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Oscillation (P5)
Asynchronous oscillation
4) Stopping times at reversal points:
● OST1[oscillation axis] = stop time at reversal point 1 in [s]
● OST2[oscillation axis] = stop time at reversal point 2 in [s]
A stop time is entered into the appropriate setting data in synchronism with the block in the
main run and thus remains effective until the setting data is next changed.
The unit for the stop time is identical to the unit selected for the stop time programmed with G04.
5) Setting feedrate:
● FA[axis] = FValue
The feedrate is transferred to the appropriate setting data in synchronism with the block in
the main run. If the oscillation axis is moved with revolutional feedrate, the corresponding
dependencies must be indicated as described in Function Manual V1.
6) Setting control settings for sequence of movements:
● OSCTRL[oscillating axis] = (set options, reset options)
Table 12- 3
Option value
0
1
2
3
4
8
16
32
64
128
256
512
840
Positioning axis infeed.
The set options are defined as follows (the reset options deselect the settings):
Set/reset options
Meaning
Stop at next reversal point on deactivation of the oscillation movement (default).
Can only be achieved by resetting option values 1 and 2.
Stop at reversal point 1 on deactivation of the oscillation movement
Stop at reversal point 2 on deactivation of the oscillation movement
On deactivation of oscillation movement, do not approach reversal point unless
sparking-out strokes are programmed
Approach an end position after spark-out process
If the oscillation movement is aborted by delete distance-to-go, the sparking-out
strokes must then be executed and the end position approached (if programmed)
If the oscillation movement is terminated by deletion of distance-to-go, the
programmed reversal point must be approached on deactivation of the oscillation
movement.
Altered feedrate will only take effect from the next reversal point.
If feedrate setting is 0, path overlay is active, or otherwise velocity overlay
For rotary axis DC (shortest path)
Sparking-out stroke as single stroke
First approach start position
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Extended Functions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents