To assign main and sub to two consecutive switcher banks
For example, to assign the first row (first switcher bank) to M/E-1 main, and
the second row (second switcher bank) to M/E-1 sub, use the following
procedure.
1
2
3
Note
It is not possible to assign the combinations of Main with Main&Sub, or Sub
with Main&Sub.
Assigning the [MAIN] and [SUB] delegation buttons to buttons
on the control panel
You can assign the [MAIN] and [SUB] delegation buttons to any of the
following three places.
To assign to the pattern limit buttons (PTN LIMIT and LIMIT SET) in
the transition control block
For details of the transition control block, see page 247.
1
2
228
Multi Program 2
Sub: use for sub operations.
Main&Sub: use for both main and sub operations.
When "Main&Sub" is selected, it is necessary to assign [MAIN] and
[SUB] delegation buttons to the control panel.
In the status area of the Engineering Setup >Panel >Config >MP2 Main/
Sub Assign menu, select 1st Row (M/E-1), then press [Main] in the <Main/
Sub Assign> group.
Press [Dual M/E Assign] to assign M/E to two banks.
In this state, both 1st Row and 2nd Row are set to main.
Set "2nd Row" to [Sub].
This cancels the shift/non-shift assignment for dual M/E in standard mode.
In the Engineering Setup >Panel >Config menu, press [Program Button].
The Program Button menu appears.
Press [Transition Module].
The Transition Module menu appears.