Local and Remote Sensing

Local
Units are shipped from the factory configured for local programming mode
Programming
operation.
Mode
Operation
Local Mode
Figure 2.9
Default
JMP2, for switch SW1, and for rear panel connector J3. These controls are used to
select among the various options for programming, sensing, and monitoring. See
Configuration
"Configuring for Remote Programming, Sensing, and Monitoring" on page

Figure 2.9 Local Mode Default Configuration

Setting
After installing the power supply and connecting the load, set the required output
voltage and current limit according to the following front panel procedure:
Output
Voltage and
1. Turn both the voltage and current controls fully counter-clockwise.
Current Limit
2. Turn the AC power ON.
3. Press the STANDBY switch to its IN position to disable the power supply
4. Press and hold the V & I CHECK button to display the voltage and current
5. Adjust the voltage control to the required voltage (the compliance voltage for
6. Adjust the current control to the required current limit setting.
7. Release the V & I CHECK button.
Revision A
Output voltage and current limit settings are adjusted with the front panel
controls.
The sense point of the supply is at the output terminals.
The front panel OVP potentiometer determines the OVP set point. See
Over Voltage Protection (OVP)" on page 62
shows the default factory settings for the internal jumpers JMP1 and
C
B
A
JMP 1
C
8 7 6 5 4 3 2 1
B
A
JMP 2
output.
control settings on the voltmeter and ammeter displays.
applications using current mode operation).
Local and Remote Sensing
for the adjustment procedure.
Installation
"Using
48.
43